Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 73
Filtrar
1.
Int J Implant Dent ; 10(1): 14, 2024 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-38507139

RESUMEN

PURPOSE: To comprehensively assess the existing literature regarding the rapidly evolving in vivo application of magnetic resonance imaging (MRI) for potential applications, benefits, and challenges in dental implant surgery. METHODS: Electronic and manual searches were conducted in PubMed MEDLINE, EMBASE, Biosis, and Cochrane databases by two reviewers following the PICOS search strategy. This involved using medical subject headings (MeSH) terms, keywords, and their combinations. RESULTS: Sixteen studies were included in this systematic review. Of the 16, nine studies focused on preoperative planning and follow-up phases, four evaluated image-guided implant surgery, while three examined artifact reduction techniques. The current literature highlights several MRI protocols that have recently investigated and evaluated the in vivo feasibility and accuracy, focusing on its potential to provide surgically relevant quantitative and qualitative parameters in the assessment of osseointegration, peri-implant soft tissues, surrounding anatomical structures, reduction of artifacts caused by dental implants, and geometric accuracy relevant to implant placement. Black Bone and MSVAT-SPACE MRI, acquired within a short time, demonstrate improved hard and soft tissue resolution and offer high sensitivity in detecting pathological changes, making them a valuable alternative in targeted cases where CBCT is insufficient. Given the data heterogeneity, a meta-analysis was not possible. CONCLUSIONS: The results of this systematic review highlight the potential of dental MRI, within its indications and limitations, to provide perioperative surgically relevant parameters for accurate placement of dental implants.


Asunto(s)
Implantes Dentales , Cirugía Asistida por Computador , Implantación Dental Endoósea/métodos , Oseointegración , Imagen por Resonancia Magnética
2.
Stroke ; 55(3): 613-621, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38328926

RESUMEN

BACKGROUND: Impaired cerebrovascular reactivity (CVR) has been correlated with recurrent ischemic stroke. However, for clinical purposes, most CVR techniques are rather complex, time-consuming, and lack validation for quantitative measurements. The recent adaptation of a standardized hypercapnic stimulus in combination with a blood-oxygenation-level-dependent (BOLD) magnetic resonance imaging signal as a surrogate for cerebral blood flow offers a potential universally comparable CVR assessment. We investigated the association between impaired BOLD-CVR and risk for recurrent ischemic events. METHODS: We conducted a retrospective analysis of patients with symptomatic cerebrovascular large vessel disease who had undergone a prospective hypercapnic-challenged BOLD-CVR protocol at a single tertiary stroke referral center between June 2014 and April 2020. These patients were followed up for recurrent acute ischemic events for up to 3 years. BOLD-CVR (%BOLD signal change per mm Hg CO2) was calculated on a voxel-by-voxel basis. Impaired BOLD-CVR of the affected (ipsilateral to the vascular pathology) hemisphere was defined as an average BOLD-CVR, falling 2 SD below the mean BOLD-CVR of the right hemisphere in a healthy age-matched reference cohort (n=20). Using a multivariate Cox proportional hazards model, the association between impaired BOLD-CVR and ischemic stroke recurrence was assessed and Kaplan-Meier survival curves to visualize the acute ischemic stroke event rate. RESULTS: Of 130 eligible patients, 28 experienced recurrent strokes (median, 85 days, interquartile range, 5-166 days). Risk factors associated with an increased recurrent stroke rate included impaired BOLD-CVR, a history of atrial fibrillation, and heart insufficiency. After adjusting for sex, age group, and atrial fibrillation, impaired BOLD-CVR exhibited a hazard ratio of 10.73 (95% CI, 4.14-27.81; P<0.001) for recurrent ischemic stroke. CONCLUSIONS: Among patients with symptomatic cerebrovascular large vessel disease, those exhibiting impaired BOLD-CVR in the affected hemisphere had a 10.7-fold higher risk of recurrent ischemic stroke events compared with individuals with nonimpaired BOLD-CVR.


Asunto(s)
Fibrilación Atrial , Trastornos Cerebrovasculares , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Humanos , Estudios Retrospectivos , Estudios Prospectivos , Imagen por Resonancia Magnética/métodos , Accidente Cerebrovascular/diagnóstico por imagen , Infarto Cerebral , Hipercapnia/diagnóstico por imagen , Circulación Cerebrovascular/fisiología
3.
J Craniomaxillofac Surg ; 52(1): 117-126, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37891089

RESUMEN

This study aimed to compare preoperative data relevant to third molar surgery based on radiographic orthopantomography (OPG) and orthopantomogram-like MR images (MR-OPG), using five different MR protocols. X-ray-based OPG and OPG-like MRI reconstructions from DESS, SPACE-STIR, SPACE-SPAIR, T1-VIBE-Dixon, and UTE sequences were acquired in 11 patients undergoing third molar surgery, using a 15-channel mandibular coil. Qualitative (image quality, susceptibility to artifacts, positional relationship, contact/non-contact of the inferior alveolar nerve (IAN), relationship to maxillary sinus, IAN continuity, root morphology) and quantitative (tooth length, retromolar distance, distance to the IAN, and distance to the mandible margin) parameters of the maxillary and mandibular third molars were assessed regarding inter-reader agreement and quantitative discrepancies by three calibrated readers. Radiation-free MR-OPGs generated within clinically tolerable acquisition times, which exhibited high image quality and low susceptibility to artifacts, showed no significant differences compared with X-ray-based OPGs regarding the assessment of quantitative parameters. UTE MR-OPGs provided radiographic-like images and were best suited for assessing qualitative preoperative data (positional relationship, nerve contact/non-contact, and dental root morphology) relevant to third molar surgery. For continuous and focal nerve imaging, DESS MR-OPG was superior. MR-OPGs could represent a shift towards indication-specific and modality-oriented perioperative imaging in high-risk oral and maxillofacial surgery.


Asunto(s)
Diente Impactado , Traumatismos del Nervio Trigémino , Humanos , Tercer Molar/diagnóstico por imagen , Tercer Molar/cirugía , Rayos X , Radiografía Panorámica/métodos , Imagen por Resonancia Magnética/métodos , Diente Impactado/cirugía , Extracción Dental , Espectroscopía de Resonancia Magnética , Nervio Mandibular , Mandíbula/diagnóstico por imagen , Mandíbula/cirugía , Mandíbula/inervación , Traumatismos del Nervio Trigémino/diagnóstico por imagen
4.
Brain Commun ; 5(6): fcad307, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38025281

RESUMEN

Magnetic resonance imaging (MRI) has limitations in identifying underlying tissue pathology, which is relevant for neurological diseases such as multiple sclerosis, stroke or brain tumours. However, there are no standardized methods for correlating MRI features with histopathology. Thus, here we aimed to develop and validate a tool that can facilitate the correlation of brain MRI features to corresponding histopathology. For this, we designed the Brainbox, a waterproof and MRI-compatible 3D printed container with an integrated 3D coordinate system. We used the Brainbox to acquire post-mortem ex vivo MRI of eight human brains, fresh and formalin-fixed, and correlated focal imaging features to histopathology using the built-in 3D coordinate system. With its built-in 3D coordinate system, the Brainbox allowed correlation of MRI features to corresponding tissue substrates. The Brainbox was used to correlate different MR image features of interest to the respective tissue substrate, including normal anatomical structures such as the hippocampus or perivascular spaces, as well as a lacunar stroke. Brain volume decreased upon fixation by 7% (P = 0.01). The Brainbox enabled degassing of specimens before scanning, reducing susceptibility artefacts and minimizing bulk motion during scanning. In conclusion, our proof-of-principle experiments demonstrate the usability of the Brainbox, which can contribute to improving the specificity of MRI and the standardization of the correlation between post-mortem ex vivo human brain MRI and histopathology. Brainboxes are available upon request from our institution.

5.
Transl Stroke Res ; 2023 Oct 25.
Artículo en Inglés | MEDLINE | ID: mdl-37880561

RESUMEN

In acute ischemic stroke due to large-vessel occlusion (LVO), the clinical outcome after endovascular thrombectomy (EVT) is influenced by the extent of autoregulatory hemodynamic impairment, which can be derived from blood oxygenation level-dependent cerebrovascular reactivity (BOLD-CVR). BOLD-CVR imaging identifies brain areas influenced by hemodynamic steal. We sought to investigate the presence of steal phenomenon and its relationship to DWI lesions and clinical deficit in the acute phase of ischemic stroke following successful vessel recanalization.From the prospective longitudinal IMPreST (Interplay of Microcirculation and Plasticity after ischemic Stroke) cohort study, patients with acute ischemic unilateral LVO stroke of the anterior circulation with successful endovascular thrombectomy (EVT; mTICI scale ≥ 2b) and subsequent BOLD-CVR examination were included for this analysis. We analyzed the spatial correlation between brain areas exhibiting BOLD-CVR-associated steal phenomenon and DWI infarct lesion as well as the relationship between steal phenomenon and NIHSS score at hospital discharge.Included patients (n = 21) exhibited steal phenomenon to different extents, whereas there was only a partial spatial overlap with the DWI lesion (median 19%; IQR, 8-59). The volume of steal phenomenon outside the DWI lesion showed a positive correlation with overall DWI lesion volume and was a significant predictor for the NIHSS score at hospital discharge.Patients with acute ischemic unilateral LVO stroke exhibited hemodynamic steal identified by BOLD-CVR after successful EVT. Steal volume was associated with DWI infarct lesion size and with poor clinical outcome at hospital discharge. BOLD-CVR may further aid in better understanding persisting hemodynamic impairment following reperfusion therapy.

6.
Imaging Sci Dent ; 53(2): 161-168, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37405200

RESUMEN

Nasopalatine duct cysts (NPDCs), the most common non-odontogenic cysts of maxilla, are often incidental findings on diagnostic imaging. When symptomatic, they usually present as a painless swelling with possible fistula. Conventional radiography shows a round-to-ovoid or heart-shaped radiolucency between the roots of central maxillary incisors. While the radiographic features of NPDCs in X-ray-based modalities have been well described, their magnetic resonance imaging (MRI) features have rarely been reported. Developments in dental MRI in recent years and the introduction of various dental MRI protocols now allow a wide range of applications in dental medicine. MRI is becoming an important tool for the detection and diagnosis of incidental or non-incidental dentomaxillofacial cysts. This report presented and discussed the characteristics of 2 NPDC cases visualized on MRI using both conventional and newly implemented specific dental MRI protocols with a novel 15-channel mandibular coil, demonstrating the use of these protocols for radiation-free maxillofacial diagnoses.

7.
Clin Neuroradiol ; 33(4): 1115-1122, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37401949

RESUMEN

PURPOSE: The 3D time-of-flight (TOF) magnetic resonance angiography (MRA) at 3T shows high sensitivity for intracranial aneurysms but is inferior to three-dimensional digital subtraction angiography (3D-DSA) regarding aneurysm characteristics. We applied an ultra-high-resolution (UHR) TOF-MRA using compressed sensing reconstruction to investigate the diagnostic performance in preinterventional evaluation of intracranial aneurysms compared to conventional TOF-MRA and 3D-DSA. METHODS: In this study 17 patients with unruptured intracranial aneurysms were included. Aneurysm dimensions, configuration, image quality and sizing of endovascular devices were compared between conventional TOF-MRA at 3T and UHR-TOF with 3D-DSA as gold standard. Quantitatively, contrast-to-noise ratios (CNR) were compared between TOF-MRAs. RESULTS: On 3D-DSA, 25 aneurysms in 17 patients were detected. On conventional TOF, 23 aneurysms were detected (sensitivity: 92.6%). On UHR-TOF, 25 aneurysms were detected (sensitivity: 100%). Image quality was not significantly different between TOF and UHR-TOF (p = 0.17). Aneurysm dimension measurements were significantly different between conventional TOF (3.89 mm) and 3D-DSA (4.2 mm, p = 0.08) but not between UHR-TOF (4.12 mm) and 3D-DSA (p = 0.19). Irregularities and small vessels at the aneurysm neck were more frequently correctly depicted on UHR-TOF compared to conventional TOF. Comparison of the planned framing coil diameter and flow-diverter (FD) diameter revealed neither a statistically significant difference between TOF and 3D-DSA (coil p = 0.19, FD p = 0.45) nor between UHR-TOF and 3D-DSA (coil: p = 0.53, FD 0.33). The CNR was significantly higher in conventional TOF (p = 0.009). CONCLUSION: In this pilot study, ultra-high-resolution TOF-MRA visualized all aneurysms and accurately depicted aneurysm irregularities and vessels at the base of the aneurysm comparably to DSA, outperforming conventional TOF. UHR-TOF with compressed sensing reconstruction seems to represent a non-invasive alternative to pre-interventional DSA for intracranial aneurysms.


Asunto(s)
Embolización Terapéutica , Aneurisma Intracraneal , Humanos , Aneurisma Intracraneal/patología , Estudios de Seguimiento , Proyectos Piloto , Angiografía por Resonancia Magnética/métodos , Angiografía de Substracción Digital/métodos , Sensibilidad y Especificidad
8.
Magn Reson Imaging ; 103: 124-130, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37481092

RESUMEN

INTRODUCTION: Brain areas exhibiting negative blood oxygenation-level dependent cerebrovascular reactivity (BOLD-CVR) responses to carbon dioxide (CO2) are thought to suffer from a completely exhausted autoregulatory cerebrovascular reserve capacity and exhibit vascular steal phenomenon. If this assumption is correct, the presence of vascular steal phenomenon should subsequently result in an equal negative fMRI signal response during a motor-task based BOLD-fMRI study (increase in metabolism without an increase in cerebral blood flow due to exhausted reserve capacity) in otherwise functional brain tissue. To investigate this premise, the aim of this study was to further investigate motor-task based BOLD-fMRI signal responses in brain areas exhibiting negative BOLD-CVR. MATERIAL AND METHODS: Seventy-one datasets of patients with cerebrovascular steno-occlusive disease without motor defects, who underwent a CO2-calibrated motor task-based BOLD-fMRI study with a fingertapping paradigm and a subsequent BOLD-CVR study with a precisely controlled CO2-challenge during the same MRI examination, were included. We compared BOLD-fMRI signal responses in the bilateral pre- and postcentral gyri - i.e. Region of Interest (ROI) with the corresponding BOLD-CVR in this ROI. The ROI was determined using a second level group analysis of the BOLD-fMRI task study of 42 healthy individuals undergoing the same study protocol. RESULTS: An overall decrease in BOLD-CVR was associated with a decrease in BOLD-fMRI signal response within the ROI. For patients exhibiting negative BOLD-CVR, we found both positive and negative motor-task based BOLD-fMRI signal responses. CONCLUSION: We show that the presence of negative BOLD-CVR responses to CO2 is associated with heterogeneous motor task-based BOLD-fMRI signal responses, where some patients show -more presumed- negative BOLD-fMRI signal responses, while other patient showed positive BOLD-fMRI signal responses. This finding may indicate that the autoregulatory vasodilatory reserve capacity does not always need to be completely exhausted for vascular steal phenomenon to occur.


Asunto(s)
Trastornos Cerebrovasculares , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Dióxido de Carbono , Encéfalo/diagnóstico por imagen , Encéfalo/irrigación sanguínea , Circulación Cerebrovascular/fisiología
10.
Transl Psychiatry ; 13(1): 136, 2023 04 28.
Artículo en Inglés | MEDLINE | ID: mdl-37117179

RESUMEN

Altered intrinsic brain connectivity of patients with anorexia nervosa has been observed in the acute phase of the disorder, but it remains unclear to what extent these alterations recover during weight normalization. In this study, we used functional imaging data from three time points to probe longitudinal changes in intrinsic connectivity patterns in patients with severe anorexia nervosa (BMI ≤ 15.5 kg/m2) over the course of weight normalization. At three distinct stages of inpatient treatment, we examined resting-state functional connectivity in 27 women with severe anorexia nervosa and 40 closely matched healthy controls. Using network-based statistics and graph-theoretic measures, we examined differences in global network strength, subnetworks with altered intrinsic connectivity, and global network topology. Patients with severe anorexia nervosa showed weakened intrinsic connectivity and altered network topology which did not recover during treatment. The persistent disruption of brain networks suggests sustained alterations of information processing in weight-recovered severe anorexia nervosa.


Asunto(s)
Anorexia Nerviosa , Mapeo Encefálico , Humanos , Femenino , Anorexia Nerviosa/diagnóstico por imagen , Imagen por Resonancia Magnética , Vías Nerviosas , Encéfalo/diagnóstico por imagen
11.
Sci Rep ; 13(1): 6228, 2023 04 17.
Artículo en Inglés | MEDLINE | ID: mdl-37069287

RESUMEN

This prospective study aimed to present, compare, and evaluate the suitability of five different magnetic resonance imaging (MRI) protocols (3D double-echo steady-state (DESS), 3D fast spin echo short-tau inversion recovery (SPACE-STIR), 3D fast spin echo spectral attenuated inversion recovery (SPACE-SPAIR), volumetric interpolated breath-hold examination (T1-VIBE-Dixon), and ultrashort echo time (UTE)) and for orthopantomogram (OPG)-like MRI reconstructions using a novel mandibular coil. Three readers assessed MR-OPGs of 21 volunteers regarding technical image quality (4, excellent; 0, severely reduced), susceptibility to artifacts (3, absence; 0, massive), and visualization of anatomical structures in the oral cavity and surrounding skeletal structures (4, fine details visible; 0, no structures visible). Average image quality was good (3.29 ± 0.83) for all MRI protocols, with UTE providing the best image quality (3.52 ± 0.62) and no to minor artifacts (2.56 ± 0.6). Full diagnostic interpretability of the osseous structures is best in VIBE-Dixon and UTE MR-OPGs. DESS provided excellent visualization of the finest details of the nervous tissue (3.95 ± 0.22). Intra-reader and inter-reader agreement between the readers was good to excellent for all protocols (ICCs 0.812-0.957). MR-OPGs provide indication-specific accurate imaging of the oral cavity and could contribute to the early detection of pathologies, staging, and radiological follow-up of oral and maxillofacial diseases.


Asunto(s)
Operatoria Dental , Cirugía Bucal , Humanos , Radiografía Panorámica , Prueba de Estudio Conceptual , Estudios Prospectivos , Imagen por Resonancia Magnética/métodos , Imagenología Tridimensional/métodos
12.
Oral Radiol ; 39(1): 1-17, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-35397042

RESUMEN

In recent years, magnetic resonance imaging (MRI) has made great strides through various technical improvements and new sequences, which have made it one of the most promising and leading imaging techniques in the head and neck region. As modern imaging techniques in dentistry aim to reduce radiation exposure, this systematic review evaluated the possibilities, advantages, and disadvantages of advanced imaging diagnostics using dental MRI and its evidence for clinical indications and limitations relevant to mandibular third molar (MTM) surgery. Two reviewers performed multiple database searches (PubMed MEDLINE, EMBASE, Biosis, and Cochrane databases) following the PICOS search strategy using medical subject headings (MeSH) terms, keywords, and their combinations. Ten studies were included in this systematic review. By providing high spatial resolution and excellent soft tissue contrast, black bone MRI sequences such as 3D Double Echo Steady State (DESS) and 3D Short Tau Inversion Recovery (STIR) imaging protocols have the potential to become a valuable alternative to cone-beam computed tomography (CBCT) in future dental clinical routines. Overall, radiation-free MRI represents another step toward personalized dentistry and improved decision-making that avoids ineffectiveness and minimizes risks in oral surgery by taking into account additional patient-side factors such as comorbidity, anatomical norm variations, and imaging biomarkers.


Asunto(s)
Imagen por Resonancia Magnética , Tercer Molar , Humanos , Tercer Molar/diagnóstico por imagen , Tercer Molar/cirugía , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada de Haz Cónico/métodos
13.
Clin Implant Dent Relat Res ; 25(1): 35-45, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36454235

RESUMEN

PURPOSE: To evaluate image quality and diagnostic accuracy of buccal bone thickness assessment in maxillary and mandibular anterior region using cone-beam computed tomography (CBCT) and 3-dimensional double-echo steady-state (DESS) MRI for preoperative planning of immediate dental implants in healthy individuals. METHODS: One hundred and twenty teeth in 10 volunteers were retrospectively evaluated for image quality and artifacts using Likert scale (4 = excellent to 0 = decreased). Buccal bone thickness was measured at three measurement points (M1 = 2 mm from the cementoenamel junction, M2 = middle of the root, and M3 = at the root apex) for each tooth in the maxillary (13-23) and the mandibular anterior region (33-43). Descriptive statistics and two-way ANOVA with Tukey's Post-hoc test were performed to evaluate the significant differences (α = 0.05) between both imaging modalities. RESULTS: Image quality showed little to no artifacts and enabled confident diagnostic interpretation (CBCT (3.72 ± 0.46); MRI (3.65 ± 0.49)), with no significant differences between both imaging modalities (p > 0.05). Regarding the assessment of buccal bone thickness at M1-M3 for the teeth 13-23 and 33-43, no significant differences were noted (p > 0.05). MRI demonstrated slight, nonsignificant overestimation of thickness with the canines having mainly a thick buccal bone wall, where thin buccal wall was evident for the central incisors. CONCLUSION: Black bone MRI sequences, such as 3D-DESS MRI, for immediate implant planning provided confidential diagnostic accuracy in bone thickness assessment without significant disadvantages compared to CBCT. Thus, the implementation of no-dose protocols for dental rehabilitation using an immediate loading approach seems promising and could further improve the treatment strategy for dental rehabilitation.


Asunto(s)
Implantes Dentales , Proyectos Piloto , Proceso Alveolar , Estudios Retrospectivos , Incisivo , Maxilar , Tomografía Computarizada de Haz Cónico
14.
AJNR Am J Neuroradiol ; 45(1): 37-43, 2023 Dec 29.
Artículo en Inglés | MEDLINE | ID: mdl-38164571

RESUMEN

BACKGROUND AND PURPOSE: Resting brain tissue perfusion in cerebral steno-occlusive vascular disease can be assessed by MR imaging using gadolinium-based susceptibility contrast agents. Recently, transient hypoxia-induced deoxyhemoglobin has been investigated as a noninvasive MR imaging contrast agent. Here we present a comparison of resting perfusion metrics using transient hypoxia-induced deoxyhemoglobin and gadolinium-based contrast agents in patients with known cerebrovascular steno-occlusive disease. MATERIALS AND METHODS: Twelve patients with steno-occlusive disease underwent DSC MR imaging using a standard bolus of gadolinium-based contrast agent compared with transient hypoxia-induced deoxyhemoglobin generated in the lungs using an automated gas blender. A conventional multi-slice 2D gradient echo sequence was used to acquire the perfusion data and analyzed using a standard tracer kinetic model. MTT, relative CBF, and relative CBV maps were generated and compared between contrast agents. RESULTS: The spatial distributions of the perfusion metrics generated with both contrast agents were consistent. Perfusion metrics in GM and WM were not statistically different except for WM MTT. CONCLUSIONS: Cerebral perfusion metrics generated with noninvasive transient hypoxia-induced changes in deoxyhemoglobin are very similar to those generated using a gadolinium-based contrast agent in patients with cerebrovascular steno-occlusive disease.


Asunto(s)
Trastornos Cerebrovasculares , Medios de Contraste , Hemoglobinas , Humanos , Gadolinio , Imagen por Resonancia Magnética/métodos , Hipoxia , Perfusión , Circulación Cerebrovascular
15.
Invest Ophthalmol Vis Sci ; 63(9): 18, 2022 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-35960514

RESUMEN

Purpose: To quantitatively assess lateral geniculate nucleus (LGN) volume loss in the presence of lesions in the postgeniculate pathway and its correlation with optical coherence tomography retinal parameters. Methods: This was a case control study of patients recruited at the University Hospital Zurich, Switzerland. Nine patients who were suffering from lesions in the postgeniculate pathway acquired at least 3 months earlier participated. Retinal parameters were analyzed using spectral domain optical coherence tomography and a newly developed magnetic resonance imaging protocol with improved contrast to noise ratio was applied to measure LGN volume. Results: The affected LGN volume in the patients (mean volume 73.89 ± 39.08 mm3) was significantly smaller compared with the contralateral unaffected LGN (mean volume 131.43 ± 12.75 mm3), as well as compared with healthy controls (mean volume 107 ± 24.4 mm3). Additionally, the ganglion cell layer thickness corresponding with the affected versus unaffected side within the patient group differed significantly (mean thickness 40.5 ± 4.11 µm vs 45.7 ± 4.79 µm) compared with other retinal parameters. A significant linear correlation could also be shown between relative LGN volume loss and ganglion cell layer thickness decrease. Conclusions: Corresponding LGN volume reduction could be shown in patients with postgeniculate lesions using a newly developed magnetic resonance imaging protocol. LGN volume decrease correlated with ganglion cell layer thickness reduction as a sign of trans-synaptic retrograde neuronal degeneration.


Asunto(s)
Cuerpos Geniculados , Retina , Estudios de Casos y Controles , Humanos , Imagen por Resonancia Magnética/métodos , Tomografía de Coherencia Óptica , Vías Visuales/diagnóstico por imagen , Vías Visuales/patología
16.
J Imaging ; 8(5)2022 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-35621910

RESUMEN

Soft-tissue lesions in the oral cavity, one of the most common sites for tumors and tumor-like lesions, can be challenging to diagnose and treat due to the wide spectrum from benign indolent to invasive malignant lesions. We report an abnormally large, rapidly growing hyperplastic lesion originating from the buccal mucosa in a 28-year-old male patient. Clinical examination revealed a well-circumscribed, smooth-surfaced, pinkish nodular lesion measuring 2.3 × 2 cm, which suggested the differential diagnosis of irritation fibroma, pyogenic granuloma, oral lipoma, and other benign or malignant neoplasms such as hemangioma, non-Hodgkin's lymphoma, or metastases to the oral cavity. Dental MRI using a 15-channel mandibular coil was performed to improve perioperative radiological and surgical management, avoiding adverse intraoperative events and misdiagnosis of vascular malformations, especially hemangiomas. Black bone MRI protocols such as STIR (short-tau inversion recovery) and DESS (double-echo steady-state) were used for high-resolution radiation-free imaging. Radiologic findings supported the suspected diagnosis of an irritation fibroma and ruled out any further head and neck lesions, therefore complete surgical resection was performed. Histology confirmed the tentative diagnosis. This article evaluates the use of this novel technique for MR diagnosis in the perioperative management of soft-tissue tumors in oral and maxillofacial surgery.

17.
J Imaging ; 8(3)2022 Mar 17.
Artículo en Inglés | MEDLINE | ID: mdl-35324630

RESUMEN

Injury to the peripheral branches of the trigeminal nerve, particularly the lingual nerve (LN) and the inferior alveolar nerve (IAN), is a rare but serious complication that can occur during oral and maxillofacial surgery. Mandibular third molar surgery, one of the most common surgical procedures in dentistry, is most often associated with such a nerve injury. Proper preoperative radiologic assessment is hence key to avoiding neurosensory dysfunction. In addition to the well-established conventional X-ray-based imaging modalities, such as panoramic radiography and cone-beam computed tomography, radiation-free magnetic resonance imaging (MRI) with the recently introduced black-bone MRI sequences offers the possibility to simultaneously visualize osseous structures and neural tissue in the oral cavity with high spatial resolution and excellent soft-tissue contrast. Fortunately, most LN and IAN injuries recover spontaneously within six months. However, permanent damage may cause significant loss of quality of life for affected patients. Therefore, therapy should be initiated early in indicated cases, despite the inconsistency in the literature regarding the therapeutic time window. In this report, we present the visualization of two cases of nerve pathology using 3D double-echo steady-state MRI and evaluate evidence-based decision-making for iatrogenic nerve injury regarding a wait-and-see strategy, conservative drug treatment, or surgical re-intervention.

18.
Clin Oral Investig ; 26(2): 2043-2053, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34586501

RESUMEN

OBJECTIVES: To assess the lingual nerve (LN) visualization using a 3D double-echo steady-state MRI sequence (3D-DESS). MATERIALS AND METHODS: Three readers prospectively evaluated the LN for its continuous visibility in 3D-DESS MRI in 19 patients with an indication for removal of mandibular impacted third molars, using a 5-point scale (4 = excellent to 0 = none). Six LN anatomical intermediate points (IP) were selected and checked for their detectability by a 4-point scale (4 = yes to1 = no). Inter- and intra-rater agreement was evaluated using intraclass correlation coefficient and percentage of agreement. RESULTS: The average nerve continuity score was 3.3 ± 0.46. In 35% of the cases, the entire course was continuously visible. In 10%, the proximal and 60%, the distal part of the nerve was not continuously visible. Inter- and intra-reader agreement was good (ICC = 0.76, ICC = 0.75). The average detectability score of all IP was 3.7 ± 0.41. From IP1 to IP5, the detectability was excellent; meanwhile, IP6 had lower visibility. The inter- and intra-reader percentage of agreement was 77% and 87%. CONCLUSIONS: The 3D-DESS sequence allowed accurate and continuous visualization of the LN with high reproducibility in more than one-third of the patients. This could improve the preoperative clarification of the LN position and thereby reduce complications during dentoalveolar surgical interventions. CLINICAL RELEVANCE: 3D-DESS MRI might be beneficial in clinical scenarios where the second molar is elongated or presents a difficult rotational position while simultaneously having a close positional relationship to the third molar. Thereby, osteotomy performed more lingually, indicating extended lingual flap detachment may increase the risk of LN damage.


Asunto(s)
Nervio Lingual , Tercer Molar , Humanos , Imagen por Resonancia Magnética , Mandíbula/diagnóstico por imagen , Mandíbula/cirugía , Tercer Molar/diagnóstico por imagen , Tercer Molar/cirugía , Reproducibilidad de los Resultados , Extracción Dental
19.
Diagnostics (Basel) ; 11(12)2021 12 20.
Artículo en Inglés | MEDLINE | ID: mdl-34943635

RESUMEN

Transcatheter aortic valve implantation (TAVI) is an alternative to open heart surgery in the treatment of symptomatic aortic valve stenosis, which is often the treatment of choice in elderly and frail patients. It carries a risk of embolic complications in the whole cerebral vascular bed, which includes the retinal vasculature. The main objective was the evaluation of retinal emboli visible on optical coherence tomography angiography (OCTA) following TAVI. This is a prospective, single center, observational study enrolling consecutive patients over two years. Patients were assessed pre- and post-TAVI. Twenty-eight patients were included in the final analysis, 82.1% were male, median age was 79.5 (range 52-88), median BCVA was 82.5 letters (range 75-93). Eight patients (28.6%) presented new capillary dropout lesions in their post-TAVI OCTA scans. There was no statistically significant change in BCVA. Quantitative analysis of macular or peripapillary OCTA parameters did not show any statistically significant difference in pre- and post-intervention. In conclusion, capillary dropout lesions could frequently be found in patients after TAVI. Quantitative measurements of macular and peripapillary flow remained stable, possibly indicating effective ocular blood flow regulation within the range of left ventricular ejection fraction in our cohort.

20.
Front Neurol ; 12: 723805, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34621237

RESUMEN

Background: Visual snow is considered a disorder of central visual processing resulting in a perturbed perception of constant binocular flickering or pixilation of the whole visual field. The underlying neurophysiological and structural alterations remain elusive. Methods: In this study, we included patients (final n = 14, five dropouts; five females, mean age: 32 years) with visual snow syndrome (VSS) and age- and sex-matched controls (final n = 20, 6 dropouts, 13 females, mean age: 28.2 years). We applied diffusion tensor imaging to examine possible white matter (WM) alterations in patients with VSS. Results: The patient group demonstrated higher (p-corrected < 0.05, adjusted for age and sex) fractional anisotropy (FA) and lower mean diffusivity (MD) and radial diffusivity (RD) compared to controls. These changes were seen in the prefrontal WM (including the inferior fronto-occipital fascicle), temporal and occipital WM, superior and middle longitudinal fascicle, and sagittal stratum. When additionally corrected for migraine or tinnitus-dominant comorbidities in VSS-similar group differences were seen for FA and RD, but less pronounced. Conclusions: Our results indicate that patients with VSS present WM alterations in parts of the visual cortex and outside the visual cortex. As parts of the inferior fronto-occipital fascicle and sagittal stratum are associated with visual processing and visual conceptualisation, our results suggest that the WM alterations in these regions may indicate atypical visual processing in patients with VSS. Yet, the frequent presence of migraine and other comorbidities such as tinnitus in VSS makes it difficult to attribute WM disruptions solely to VSS.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...